Assess the condition of wind turbine blades, including cracks, erosion, and lightning damage, with this specialized online template. Document defects and repair recommendations.
Start your wind turbine blade inspection report now
Take photos of the object in the mobile app, complete the inspection report from the template, and download the finished photo report as Word or PDF.
Capture photos of blade conditions on site with the mobile app, then import them directly into your wind turbine blade inspection report.
Mobile AppComplete the document from this template: sections, fields, photo documentation, and signatures.
Create a professional photo annex of blade defects using the photo report generator, enhancing your blade inspection report.
Create Photo ReportReport
Review the structure, sections, and fields before proceeding to fill out the document.
No.WB-2026-07-14-001
The general information about the inspected wind power installations, including their location, identification, and the purpose of the inspection, is presented.
| Inspection date | 7/14/2026 | Address | Green Valley Wind Farm, Turbine T-07, Springfield, IL 62701 |
| Basis for inspection | Annual blade inspection |
The inspection covered all wind turbines within the designated area, and no discrepancies were found in the general data.
The object of inspection includes wind turbine generators, their foundations, towers, nacelles, rotors, and associated electrical and control systems.
| Object type | Wind Turbine Blade | Object name | Blade A - Turbine T-07 |
| Technical condition | not filled in | Release date | 3/15/2020 |
| Start of operation | 6/1/2020 |
The inspected objects were identified and verified against the provided technical passports and registration documents.
The main technical parameters of the wind power installations, such as rated power, rotor diameter, hub height, and generator type, were verified against the design documentation.
| Blade Position | 0° | Blade Length | 58.5 |
| Blade Material | Fiberglass |
All main parameters correspond to the design values and manufacturer specifications.
The operating conditions of the wind power installations, including wind speed, temperature, and load factors, were recorded and analyzed.
The installations were operating within the specified environmental and operational limits.
List defects found on the blade, including type, location, severity, and photos.
| No. | Damage description | Photos |
|---|---|---|
| 1 | - | not filled in |
| 2 | - | not filled in |
Provide overall condition assessment and repair recommendations.
| Identification was carried out | Blade A of Turbine T-07 |
| There are remarks | Leading edge erosion on blade A; lightning protection functional. |
Record the inspector and facility manager.
| No. | Full name | Position / status | Comment |
|---|---|---|---|
| 1 | Robert Wilson | Inspector | Conducted blade inspection |
| 2 | Anna Green | Facility Manager | Reviewed report |
Capture digital signatures of inspector and manager.
Report
This report focuses on the condition of wind turbine blades, documenting surface condition, leading and trailing edge condition, lightning protection status, and defects such as cracking, erosion, delamination, and lightning damage.
The template provides a specialized format for blade inspections, with sections for blade details, condition assessment, defects, observations, and repair recommendations. It ensures thorough documentation for maintenance and safety.
The report includes inspection identification, blade details, blade condition, defects, observations, conclusions and recommendations, and signatures.
Use this report for routine annual blade inspections to monitor condition and plan repairs.
After a lightning strike, inspect blades for damage to the surface and lightning protection system.
Track blade condition over time to prioritize repairs and replacements.
Identify defects like erosion or delamination that may affect aerodynamic performance and energy production.
The report may serve as evidence for warranty claims or insurance assessments related to blade damage.
Ensure that blades are structurally sound and safe for continued operation.
Prepare for blade inspection by ensuring safe access. Use rope access, drones, or platforms as needed.
Conduct a preliminary visual inspection from the ground using binoculars or cameras.
Perform a close-up inspection of the blade surface, leading edge, trailing edge, and lightning protection system.
Mark and photograph each defect, noting its location, type, and severity.
Compile all findings, photos, and repair recommendations into the report. Obtain signatures from the inspector and facility manager.
Create a professional photo annex of blade defects using the photo report generator, enhancing your blade inspection report.
Create Photo ReportCapture photos of blade conditions on site with the mobile app, then import them directly into your wind turbine blade inspection report.
Mobile AppClick a section to jump to it in the sample document.
The general information about the inspected wind power installations, including their location, identification, and the purpose of the inspection, is presented.
The object of inspection includes wind turbine generators, their foundations, towers, nacelles, rotors, and associated electrical and control systems.
The main technical parameters of the wind power installations, such as rated power, rotor diameter, hub height, and generator type, were verified against the design documentation.
The operating conditions of the wind power installations, including wind speed, temperature, and load factors, were recorded and analyzed.
List defects found on the blade, including type, location, severity, and photos.
Provide overall condition assessment and repair recommendations.
Record the inspector and facility manager.
Capture digital signatures of inspector and manager.
The report assesses surface condition, leading edge condition, trailing edge condition, and lightning protection status. Each is rated as good, fair, or poor.
Common defects include cracking, erosion, delamination, lightning damage, and coating failure. Each defect can be described with location, severity, and photos.
Yes, the template includes a defect photo field for each defect. You can attach close-up and overview photos.
The report is typically signed by the inspector and the wind farm manager. Signatures confirm the findings and repair recommendations.
Yes, the template allows you to specify blade position, length, and material, making it adaptable for various blade designs.
Enter inspection details and generate a ready-to-download document.