Mobile Photo Documentation App
Capture photos of foundation conditions on site with the mobile app, then import them directly into your wind farm foundation inspection report.
Mobile AppReport
Assess the condition of wind turbine foundations, including concrete and anchor bolts, with this comprehensive online template. Document defects and observations.
Start your wind farm foundation inspection report now
Take photos of the object in the mobile app, complete the inspection report from the template, and download the finished photo report as Word or PDF.
Capture photos of foundation conditions on site with the mobile app, then import them directly into your wind farm foundation inspection report.
Mobile AppComplete the document from this template: sections, fields, photo documentation, and signatures.
Create a professional photo annex of foundation defects and anchor bolts using the photo report generator, enhancing your inspection report.
Create Photo ReportReport
Review the structure, sections, and fields before proceeding to fill out the document.
No.WF-2026-07-14-001
The general information about the inspected wind power installations, including their location, identification, and the purpose of the inspection, is presented.
| Inspection date | 7/14/2026 | Address | Green Valley Wind Farm, Turbine T-07, Springfield, IL 62701 |
| Basis for inspection | Annual foundation inspection |
The inspection covered all wind turbines within the designated area, and no discrepancies were found in the general data.
The object of inspection includes wind turbine generators, their foundations, towers, nacelles, rotors, and associated electrical and control systems.
| Object type | Wind Turbine Foundation | Object name | Foundation F-07 |
| Technical condition | not filled in | Release date | 3/15/2020 |
| Start of operation | 6/1/2020 |
The inspected objects were identified and verified against the provided technical passports and registration documents.
The main technical parameters of the wind power installations, such as rated power, rotor diameter, hub height, and generator type, were verified against the design documentation.
| Foundation Type | Gravity | Concrete Grade | C35/45 |
| Age of Foundation | 6 |
All main parameters correspond to the design values and manufacturer specifications.
The operating conditions of the wind power installations, including wind speed, temperature, and load factors, were recorded and analyzed.
The installations were operating within the specified environmental and operational limits.
List defects in concrete (cracks, spalling) and anchor bolts (corrosion, torque).
| No. | Damage description | Photos |
|---|---|---|
| 1 | - | not filled in |
| 2 | - | not filled in |
Provide overall condition assessment and recommendations.
| Identification was carried out | Foundation F-07 |
| There are remarks | Concrete condition is fair; hairline cracks observed on north face. Anchor bolts torque within limits. |
Record the inspector and wind farm manager.
| No. | Full name | Position / status | Comment |
|---|---|---|---|
| 1 | James Taylor | Inspector | Conducted inspection |
| 2 | Anna Green | Facility Manager | Reviewed report |
Capture digital signatures of inspector and manager.
Report
This report documents the inspection of wind turbine foundations, focusing on concrete condition, cracks, spalling, and anchor bolt integrity. It includes visual inspection, bolt torque checks, and defect recording.
The template provides a structured format for inspecting foundation components, with repeatable sections for anchor bolts and defects. It ensures thorough documentation for maintenance and safety.
The report includes inspection identification, foundation details, visual inspection, anchor bolt inspection, defects, observations, conclusions and recommendations, and signatures.
Use this report for routine annual inspections of wind turbine foundations to monitor condition and plan maintenance.
After an earthquake, inspect foundations for settlement, cracks, and anchor bolt damage.
Track foundation condition over time to prioritize repairs and replacements.
Ensure that foundations are structurally sound and safe for continued operation.
The report may serve as evidence for warranty claims or insurance assessments related to foundation defects.
During construction, use this report to verify that foundations meet specifications.
Inspect the concrete surface for cracks, spalling, exposed rebar, and other defects. Record findings.
Measure the torque of each anchor bolt and check for corrosion. Record values and condition.
If needed, take concrete core samples for laboratory testing to assess strength and durability.
Compile all findings, photos, and recommendations into the report. Obtain signatures from the inspector and facility manager.
Create a professional photo annex of foundation defects and anchor bolts using the photo report generator, enhancing your inspection report.
Create Photo ReportCapture photos of foundation conditions on site with the mobile app, then import them directly into your wind farm foundation inspection report.
Mobile AppClick a section to jump to it in the sample document.
The general information about the inspected wind power installations, including their location, identification, and the purpose of the inspection, is presented.
The object of inspection includes wind turbine generators, their foundations, towers, nacelles, rotors, and associated electrical and control systems.
The main technical parameters of the wind power installations, such as rated power, rotor diameter, hub height, and generator type, were verified against the design documentation.
The operating conditions of the wind power installations, including wind speed, temperature, and load factors, were recorded and analyzed.
List defects in concrete (cracks, spalling) and anchor bolts (corrosion, torque).
Provide overall condition assessment and recommendations.
Record the inspector and wind farm manager.
Capture digital signatures of inspector and manager.
The report covers concrete condition (cracks, spalling, exposed rebar), anchor bolt torque and corrosion, and overall structural integrity.
Each anchor bolt is inspected individually, with measurements of torque, presence of corrosion, and condition notes. The section is repeatable for multiple bolts.
Yes, the template includes photo fields for defects and anchor bolts. You can attach overview and close-up photos.
The report is typically signed by the inspector and the wind farm manager. Signatures confirm the findings and recommendations.
Yes, the template allows you to specify foundation type (e.g., gravity, pile) and concrete grade, making it adaptable for various designs.
Enter inspection details and generate a ready-to-download document.