Document the visible condition of switchgear components with this structured inspection report template. Record findings for circuit breakers, disconnect switches, busbars, and protective relays in an online editor.
Start your switchgear inspection report
Take photos of the object in the mobile app, complete the inspection report from the template, and download the finished photo report as Word or PDF.
Capture switchgear inspection photos on-site with the mobile app and seamlessly integrate them into your report for accurate field documentation.
Mobile AppComplete the document from this template: sections, fields, photo documentation, and signatures.
Use the photo report generator to attach overview photos, nameplate images, and defect close-ups to your switchgear inspection report.
Create Photo ReportReport
Review the structure, sections, and fields before proceeding to fill out the document.
No.SWGR-2026-015
The general information about the inspection, including the date, location, and the inspecting organization, is provided below.
| Inspection date | 7/14/2026 | Address | Main Switchroom, Building 3, Industrial Park, 4500 Factory Rd, Detroit, MI 48201 |
The general information has been recorded accurately.
The switchgear under inspection is identified by its type, serial number, and installation location, as per the technical documentation.
| Object name | SWG-04 | Technical condition | not filled in |
| Year of Manufacture | 1/1/2018 |
The identification data of the switchgear have been verified and match the provided documentation.
The main technical parameters of the switchgear, such as rated voltage, current, and breaking capacity, were measured and compared with the manufacturer's specifications.
| Voltage Rating | 13.8 | Current Rating | 2000 |
All main parameters are within the permissible tolerances specified by the manufacturer.
The operational conditions of the switchgear, including ambient temperature, humidity, and load levels, were recorded during the inspection.
The operating conditions are within the design limits and do not adversely affect the switchgear's performance.
Document each component inspected, its visual condition, any defects observed, and required actions.
| No. | Damage description | Photos |
|---|---|---|
| 1 | - | not filled in |
Provide overall condition assessment and recommendations for follow-up.
| Identification was carried out | Switchgear Panel SWG-04 |
| There are remarks | Minor corrosion on enclosure. All components functional. |
List the inspector and any other participants involved in the inspection.
| No. | Full name | Position / status | Comment |
|---|---|---|---|
| 1 | Emily Davis | Inspector | Performed visual inspection |
| 2 | John Miller | Maintenance Engineer | Reviewed findings |
Capture digital signatures of the inspector and reviewer.
Report
A switchgear visual inspection report documents the visible condition of switchgear components. It includes identification details, visual inspection findings for each component, measurements, and an overall assessment with recommendations.
Electrical inspectors, maintenance engineers, and facility managers use this report to assess switchgear condition. It is commonly used during scheduled maintenance, pre-commissioning, and troubleshooting.
The report includes sections for inspection identification, switchgear identification, visual inspection findings (repeatable), measurements, conclusions and recommendations, and signatures.
Maintenance teams use this report to document the condition of switchgear during routine inspections, identifying defects such as corrosion, overheating, or loose connections.
Before new switchgear is put into service, this report helps verify that all components are in good condition and free from defects.
The report captures defects with severity levels and required actions, enabling maintenance planners to prioritize repairs and schedule follow-up work.
Asset managers use inspection data to track the condition of switchgear over time, supporting lifecycle management and replacement decisions.
Record the switchgear ID, manufacturer, model, voltage and current ratings, and year of manufacture.
For each component (e.g., circuit breaker, disconnect switch), assess visual condition, note any defects, and assign severity and required action.
If applicable, record measurements such as insulation resistance, contact resistance, or temperature readings.
Provide overall condition rating and recommendations. Obtain signatures from inspector and reviewer.
Use the photo report generator to attach overview photos, nameplate images, and defect close-ups to your switchgear inspection report.
Create Photo ReportCapture switchgear inspection photos on-site with the mobile app and seamlessly integrate them into your report for accurate field documentation.
Mobile AppClick a section to jump to it in the sample document.
The general information about the inspection, including the date, location, and the inspecting organization, is provided below.
The switchgear under inspection is identified by its type, serial number, and installation location, as per the technical documentation.
The main technical parameters of the switchgear, such as rated voltage, current, and breaking capacity, were measured and compared with the manufacturer's specifications.
The operational conditions of the switchgear, including ambient temperature, humidity, and load levels, were recorded during the inspection.
Document each component inspected, its visual condition, any defects observed, and required actions.
Provide overall condition assessment and recommendations for follow-up.
List the inspector and any other participants involved in the inspection.
Capture digital signatures of the inspector and reviewer.
The report supports inspection of circuit breakers, disconnect switches, busbars, protective relays, and other components. You can select the component type from a predefined list.
Predefined defects include corrosion, overheating, misalignment, vibration, loose connection, mechanical damage, insulation degradation, moisture ingress, and many more.
Yes, the measurements section allows you to record insulation resistance, contact resistance, temperature, partial discharge, or other measurement types with values and units.
Severity is selected from options: minor, medium, high, or critical. The inspector assigns severity based on the potential impact of the defect.
The report includes signature fields for the inspector and a reviewer (typically a maintenance engineer). Both signatures confirm the inspection and review.
Enter inspection details and generate a ready-to-download document.