Mobile Photo Documentation App
Capture inspection photos on-site with the mobile app. The app syncs with the online editor, making it easy to document the lightning protection system in the field.
Mobile AppReport
Generate a lightning protection system inspection report online. Record air terminal, down conductor, and grounding condition, continuity tests, and defects with photos.
Start with this template
Take photos of the object in the mobile app, complete the inspection report from the template, and download the finished photo report as Word or PDF.
Capture inspection photos on-site with the mobile app. The app syncs with the online editor, making it easy to document the lightning protection system in the field.
Mobile AppComplete the document from this template: sections, fields, photo documentation, and signatures.
Use the photo report generator to attach clear photos of air terminals, down conductors, ground connections, and defects. Visual evidence supports the inspection findings.
Create Photo ReportReport
Review the structure, sections, and fields before proceeding to fill out the document.
No.LPS-2026-0714
The inspection was carried out in accordance with the applicable standards and regulations for lightning protection systems.
| Inspection date | 7/14/2026 | Address | 45 Station Road, Birmingham B2 4EN |
| Basis for inspection | Annual inspection per BS EN 62305 |
The overall condition of the lightning protection system was assessed and documented.
The object of inspection is the lightning protection system installed on the building, including air terminals, down conductors, and grounding electrodes.
| Object type | Lightning Protection System | Object name | Westgate Tower |
| Technical condition | not filled in |
The identification and location of the lightning protection system components were verified.
List each defect with component, defect type, description, location, severity, and photo.
| No. | Damage description | Photos |
|---|---|---|
| 1 | - 1 | not filled in |
| 2 | - 1 | not filled in |
Provide overall condition, compliance status, and recommendations.
| Identification was carried out | Building: Westgate Tower |
| There are remarks | Overall condition: Satisfactory. Minor corrosion on one air terminal. |
List the inspector and building owner involved.
| No. | Full name | Position / status | Comment |
|---|---|---|---|
| 1 | Eleanor Clarke | Electrical Inspector | Performed inspection |
| 2 | Robert Hughes | Building Owner | Acknowledged findings |
Collect signatures from the inspector and building owner.
Report
This report documents the inspection of a building's lightning protection system, including air terminals, down conductors, surge protective devices, and grounding electrodes. It records visual condition, continuity test results, resistance measurements, and any defects found.
An online template ensures systematic data collection for each component. It helps inspectors record test results, attach photos, and generate a professional report that can be shared with building owners for compliance and maintenance planning.
Electrical inspectors, building owners, and facility managers use this report to verify that the lightning protection system is in good condition and complies with applicable standards.
Lightning protection systems should be inspected annually to ensure all components are intact and functional. This report documents the annual check.
After a lightning strike, a thorough inspection is necessary to identify any damage. This report helps document the condition and any required repairs.
Many building codes and insurance policies require regular inspection of lightning protection systems. This report serves as evidence of compliance.
The report's findings and recommendations help prioritize repairs or replacements, such as fixing loose connections or replacing end-of-life surge protective devices.
Inspect all air terminals, down conductors, grounding electrodes, and surge protective devices for visible damage, corrosion, or loose connections.
Perform continuity tests on conductors and measure ground resistance. Record the results for each component.
Enter all findings into the online template, attach photos of components and defects, and generate the report. The inspector and building owner sign the report.
Use the photo report generator to attach clear photos of air terminals, down conductors, ground connections, and defects. Visual evidence supports the inspection findings.
Create Photo ReportCapture inspection photos on-site with the mobile app. The app syncs with the online editor, making it easy to document the lightning protection system in the field.
Mobile AppClick a section to jump to it in the sample document.
The inspection was carried out in accordance with the applicable standards and regulations for lightning protection systems.
The object of inspection is the lightning protection system installed on the building, including air terminals, down conductors, and grounding electrodes.
List each defect with component, defect type, description, location, severity, and photo.
Provide overall condition, compliance status, and recommendations.
List the inspector and building owner involved.
Collect signatures from the inspector and building owner.
The inspection covers air terminals (lightning rods), down conductors, surge protective devices (SPDs), grounding electrodes, and bonding conductors. Each component is visually inspected and tested for continuity and resistance.
Continuity tests are performed on conductors to ensure electrical path integrity. Resistance measurements are taken for grounding electrodes. SPDs are checked for end-of-life indicators.
Defects are classified by type (corrosion, loose connection, conductor discontinuity, SPD end of life, damage) and severity (minor, medium, high, critical). Photos are required for medium severity and above.
The report is signed by the electrical inspector who performed the inspection and the building owner or representative. Digital signatures are supported in the online editor.
Click 'Use this template' to open it in the online editor. Fill in the inspection details, component conditions, test results, and defects. Attach photos and generate the report.
Enter inspection details and generate a ready-to-download document.