Document the condition and defects of an individual heating point (IHP) with our structured inspection act template. Record component inspections, measurements, and signatures.
Start your IHP inspection act now
Take photos of the object in the mobile app, complete the inspection report from the template, and download the finished photo report as Word or PDF.
Capture IHP inspection photos on-site with the mobile app and sync them directly to your act. It speeds up field documentation and reduces errors.
Mobile AppComplete the document from this template: sections, fields, photo documentation, and signatures.
Use the photo report generator to create professional IHP inspection acts with embedded photos and structured defect entries. It streamlines documentation.
Create Photo ReportAct
Review the structure, sections, and fields before proceeding to fill out the document.
No.IHP-2026-031
The general information about the inspection, including the date, location, and inspection team, is provided below.
| Inspection date | 7/14/2026 | Address | 42 Maple Street, Springfield, IL 62701 |
| Basis for inspection | Seasonal readiness inspection |
The inspection was conducted in accordance with the approved schedule and methodology.
The inspected object is an individual heating point (IHP) located at the specified address, serving the building's heating and hot water systems.
| Object Type | Individual Heating Point | Object Name | IHP-Building A |
| Technical State | not filled in | Release Date | 8/20/2015 |
| Start of Operation | 10/1/2015 |
The object was identified and its boundaries were established for the purpose of this inspection.
The main parameters of the IHP, including design heat load, operating temperatures, and pressure, were verified against the project documentation.
| Heat Exchanger Type | Plate | Pump Power | 1.5 |
| Meter Model | Kamstrup Multical 602 |
The main parameters comply with the design values within the permissible tolerances.
Additional parameters such as flow rates, valve settings, and control system configurations were checked for proper operation.
| Supply Temperature: 75 | Return Temperature: 50 |
No significant deviations were found in the additional parameters.
The operating conditions of the IHP, including ambient temperature, humidity, and accessibility, were assessed during the inspection.
The conditions were found to be within the normal operating range.
List and describe any defects found during inspection, including location, extent, and photos.
| No. | Damage description | Photos |
|---|---|---|
| 1 | - 15 | not filled in |
| 2 | - 1 | not filled in |
| 3 | - 5 | not filled in |
Provide overall condition assessment and recommendations.
| Identification was carried out | IHP serving building A |
| There are remarks | Heat exchanger fouling noted; pump operational. |
List the inspector, building owner, and technician involved.
| No. | Full name | Position / status | Comment |
|---|---|---|---|
| 1 | David Kim | Inspector | Lead inspector |
| 2 | Linda Gray | Building Owner | Present during inspection |
| 3 | Tom Baker | Technician | Assisted with system access |
Capture signatures of inspector and building owner.
Act
An individual heating point (IHP) inspection act is an official document that records the condition, defects, and measurements of a heating point. It is used for routine inspections, seasonal readiness checks, or handover procedures.
Inspectors, building owners, and maintenance technicians use this act to document the state of the IHP. It serves as a formal record for compliance and maintenance planning.
The act includes object identification, inspection context, component inspection, defects, observations, measurements, conclusions, and signatures.
Before the heating season, an IHP inspection act verifies that the system is ready for operation. It documents any defects that need correction.
When a new IHP is installed or ownership changes, the inspection act records the condition at handover. It helps resolve disputes about pre-existing defects.
Regular inspections help identify wear, leaks, or corrosion early. The act supports planning of maintenance and repairs.
In some jurisdictions, IHP inspections are required by regulations. The act provides documented evidence of compliance.
The inspector reviews previous records and prepares the inspection checklist. The IHP is isolated if necessary.
Each component of the IHP is visually inspected: heat exchanger, circulation pump, meters, piping, and safety devices. Defects and observations are recorded.
Operational tests are performed, including pressure checks, temperature measurements, and flow verification. Results are recorded.
The completed act is reviewed and signed by the inspector and building owner. Copies are distributed to relevant parties.
Use the photo report generator to create professional IHP inspection acts with embedded photos and structured defect entries. It streamlines documentation.
Create Photo ReportCapture IHP inspection photos on-site with the mobile app and sync them directly to your act. It speeds up field documentation and reduces errors.
Mobile AppClick a section to jump to it in the sample document.
The general information about the inspection, including the date, location, and inspection team, is provided below.
The inspected object is an individual heating point (IHP) located at the specified address, serving the building's heating and hot water systems.
The main parameters of the IHP, including design heat load, operating temperatures, and pressure, were verified against the project documentation.
Additional parameters such as flow rates, valve settings, and control system configurations were checked for proper operation.
The operating conditions of the IHP, including ambient temperature, humidity, and accessibility, were assessed during the inspection.
List and describe any defects found during inspection, including location, extent, and photos.
Provide overall condition assessment and recommendations.
List the inspector, building owner, and technician involved.
Capture signatures of inspector and building owner.
Common components include the heat exchanger, circulation pump, meters, piping, valves, expansion vessel, and safety devices. The template allows you to inspect any component.
Typical defects include leaks, corrosion, cracks, fouling, cavitation, bearing wear, seal leaks, meter inaccuracy, and pump failure.
Yes, the template requires photos of the overall system, insulation condition, safety devices, and any defects. Photos provide visual evidence of the IHP condition.
The inspector and the building owner or their representative sign the act. A technician may also sign if present.
Click 'Use this template' to open the online editor. You can then fill in the inspection details, add component inspections, upload photos, and generate the final document.
Enter inspection details and generate a ready-to-download document.