Gas Turbine Inspection Report
No.GT-2026-005
1. General Information
| Inspection date | 7/14/2026 | Address | Unit 1, Green Valley CCGT, 2000 Energy Dr, Austin, TX 78701 |
| Basis for inspection | Combustion inspection after 8000 hours |
2. Object of Inspection
| Object name | GT-1 | Technical condition | not filled in |
| Operating Hours, hours | 25000 |
3. Turbine Parameters
| Exhaust Gas Temperature | 540 | Compressor Discharge Pressure | 12.5 |
| Fuel Consumption | 8500 |
4. Inspection Conditions
5. Component Findings
| No. | Damage description | Photos |
|---|---|---|
| 1 | - | not filled in |
| 2 | - | not filled in |
6. Overall Assessment
| Identification was carried out | Gas Turbine GT-1 |
| There are remarks | Combustor liners show cracking. Compressor fouling present. Overall condition fair. |
7. Abbreviations and Symbols
8. Inspection Participants
| No. | Full name | Position / status | Comment |
|---|---|---|---|
| 1 | Daniel Garcia | Gas Turbine Engineer | Lead inspector |
| 2 | Karen White | Plant Manager | Reviewed findings |