Mobile Photo Documentation App
Capture photos of the pressure gauge reading and test equipment on site with the mobile app for inclusion in the certificate.
Mobile AppAct
Certify that a gas system is leak-free after installation or repair. Record test pressure, duration, pressure drop, and result. Open the template in the online editor to start.
Start with this template
Take photos of the object in the mobile app, complete the inspection report from the template, and download the finished photo report as Word or PDF.
Capture photos of the pressure gauge reading and test equipment on site with the mobile app for inclusion in the certificate.
Mobile AppComplete the document from this template: sections, fields, photo documentation, and signatures.
Generate a professional certificate with photos of the pressure gauge and test setup using the photo report generator.
Create Photo ReportAct
Review the structure, sections, and fields before proceeding to fill out the document.
No.GTTC-2026-042
The general information about the inspection, including date, location, and purpose, is provided below.
| Inspection date | 7/14/2026 | Address | 12 Station Road, Manchester M1 2AB |
The inspection was conducted in accordance with the applicable regulations and standards.
The object of inspection is the gas installation, including its components and associated systems, as described in the project documentation.
| Object type | Gas installation | Object name | New boiler gas supply pipework |
The gas installation was identified and its configuration matches the project documentation.
The main parameters of the gas installation, such as operating pressure, pipe diameters, and material specifications, were verified against the design data.
| Test Pressure | 20 | Test Duration | 2 |
| Pressure Drop | 0.5 | Test Result | Pass |
The main parameters of the gas installation comply with the design values.
Additional parameters, including safety devices, ventilation, and emergency shutdown systems, were inspected for proper installation and functionality.
| Equipment Used: Kane 458 Pressure Gauge | Observations: No leaks detected. System held pressure. |
All additional parameters meet the regulatory requirements and are in good working order.
Provides a summary of the test and any relevant notes.
| Identification was carried out | New gas pipework for boiler installation |
| There are remarks | Test passed. System is gas-tight. |
Lists the engineer and any witness present during the test.
| No. | Full name | Position / status | Comment |
|---|---|---|---|
| 1 | David Green | Gas Safe Registered Engineer | Performed test |
| 2 | Robert Wilson | Witness (Homeowner) | Present during test |
Captures the signatures of the engineer and witness to certify the test.
Act
A gas tightness test certificate is a formal document that provides evidence that a gas system has been tested for leaks and meets the required standards. It records the test pressure, duration, pressure drop, and pass/fail result.
This template is used by Gas Safe registered engineers to certify the integrity of gas pipework after installation, repair, or modification. It may also be required by building owners or regulatory bodies as proof of compliance.
The template includes sections for test details, system information, equipment used, observations, and signatures. It also requires photo evidence of the pressure gauge reading and test equipment setup.
After installing new gas pipework, this certificate confirms that the system is gas-tight and safe to use.
Following a repair or modification to existing gas pipework, a tightness test is required to ensure no leaks were introduced.
Before commissioning a gas appliance or system, this certificate provides documented proof that the pipework holds pressure.
The certificate may be submitted to building control, insurance companies, or gas network operators as part of compliance records.
Isolate the gas system and ensure all appliances are turned off.
Connect the pressure test equipment to the system and pressurize to the required test pressure.
Hold the pressure for the specified duration and monitor for any pressure drop.
If the test passes, release pressure, reconnect the system, and complete the Gas Tightness Test Certificate with all details and signatures.
Generate a professional certificate with photos of the pressure gauge and test setup using the photo report generator.
Create Photo ReportCapture photos of the pressure gauge reading and test equipment on site with the mobile app for inclusion in the certificate.
Mobile AppClick a section to jump to it in the sample document.
The general information about the inspection, including date, location, and purpose, is provided below.
The object of inspection is the gas installation, including its components and associated systems, as described in the project documentation.
The main parameters of the gas installation, such as operating pressure, pipe diameters, and material specifications, were verified against the design data.
Additional parameters, including safety devices, ventilation, and emergency shutdown systems, were inspected for proper installation and functionality.
Provides a summary of the test and any relevant notes.
Lists the engineer and any witness present during the test.
Captures the signatures of the engineer and witness to certify the test.
A gas tightness test is a pressure test performed on gas pipework to check for leaks. The system is pressurized to a specified level and held for a set duration; if the pressure drop is within acceptable limits, the test passes.
Only a Gas Safe registered engineer should perform a gas tightness test. The engineer is responsible for conducting the test correctly and completing the certificate.
The certificate records the test date, test pressure, duration, pressure drop, pass/fail result, system description, installation location, equipment details, observations, and signatures of the engineer and witness.
A witness signature is optional but recommended. The witness may be the property owner, contractor, or another engineer. The engineer's signature is mandatory.
Both documents record pressure test results, but the Gas Tightness Test Certificate is specifically for tightness tests after installation or repair, while the Gas Pressure Test Record may include other types of pressure tests (e.g., strength tests) and is more general.