Mobile Photo Documentation App
Capture photos of fire doors on-site with the mobile app and attach them directly to the report. This streamlines the data collection process.
Mobile AppReport
Ensure fire doors comply with regulations and are functional. Record inspection results, defects, photo evidence, and overall compliance status.
Start your fire door report
Take photos of the object in the mobile app, complete the inspection report from the template, and download the finished photo report as Word or PDF.
Capture photos of fire doors on-site with the mobile app and attach them directly to the report. This streamlines the data collection process.
Mobile AppComplete the document from this template: sections, fields, photo documentation, and signatures.
Use the photo report generator to create a professional fire door inspection report with embedded photos. It enhances the raw data with a polished layout.
Create Photo ReportReport
Review the structure, sections, and fields before proceeding to fill out the document.
No.FDIR-2026-07-14-006
The inspection was conducted in accordance with applicable fire safety regulations and internal procedures.
| Inspection date | 7/14/2026 | Address | East Wing, City Hospital, Liverpool L3 5TR |
The overall condition of the evacuation routes was assessed and documented.
The object of inspection is the network of evacuation routes, including corridors, stairwells, exits, and signage.
| Object name | Fire Door FD-202 |
The evacuation routes were identified and their locations verified.
Main parameters such as route width, length, and capacity were measured and compared with design specifications.
| Self-closing result | Fail | Seals condition | Good |
| Gaps result | Within limit | Hinges condition | Good |
| Latch result | Pass |
All measured parameters were found to be within acceptable limits.
Lists defects found on fire doors with descriptions and photos.
| No. | Damage description | Photos |
|---|---|---|
| 1 | - | not filled in |
Provides overall compliance status and recommended actions.
| Identification was carried out | Each door identified by its door number. |
| There are remarks | Overall compliance rate 95%; one door requires immediate attention. |
Records the inspector and building owner.
| No. | Full name | Position / status | Comment |
|---|---|---|---|
| 1 | Paul Harris | Fire Safety Officer | Inspector |
| 2 | Sarah Connor | Facilities Manager | Accompanied inspection |
Captures signatures of the inspector and building owner.
Report
This report provides a detailed record of fire door inspections, including results for self-closing, seals, gaps, hinges, and latch. It includes sections for inspection details, door results, defects, conclusion, and signatures.
The report includes inspection details, repeatable fire door results (self-closing, seals, gaps, hinges, latch, notes), defects, overall status, and signatures of inspector and building owner.
Attach photos of the full door, hinges, seals, self-closing device, and gap measurements (if gaps exceed limits). Photos provide visual proof of the door's condition.
Use this report to document annual fire door inspections as required by fire safety regulations. The detailed format supports compliance reporting.
The report helps maintenance teams identify doors that need adjustment or repair. It serves as a baseline for future inspections.
Provide the report to insurers as evidence of regular fire door maintenance. This may be required for coverage or claims.
Building owners can use the report to track the condition of fire doors across their property and prioritize maintenance budgets.
Maintain a historical record of fire door inspections for internal or external audits. The report includes signatures and dates for accountability.
When a building changes ownership or management, this report provides a snapshot of the fire doors' condition at the time of handover.
Record the inspection date, inspector name, building name, and location to establish the context.
For each door, enter its identifier and record results for self-closing, seals, gaps, hinges, and latch. Add any notes about the door's condition.
If any defects are found, describe them, note their location and severity, and attach a photo. Defects are recorded in a repeatable section.
Assess the overall status of the door as compliant, needs adjustment, or non-compliant. Add recommendations if needed.
The inspector and building owner sign the report. The completed report can be exported as a PDF or shared.
Use the photo report generator to create a professional fire door inspection report with embedded photos. It enhances the raw data with a polished layout.
Create Photo ReportCapture photos of fire doors on-site with the mobile app and attach them directly to the report. This streamlines the data collection process.
Mobile AppClick a section to jump to it in the sample document.
The inspection was conducted in accordance with applicable fire safety regulations and internal procedures.
The object of inspection is the network of evacuation routes, including corridors, stairwells, exits, and signage.
Main parameters such as route width, length, and capacity were measured and compared with design specifications.
Lists defects found on fire doors with descriptions and photos.
Provides overall compliance status and recommended actions.
Records the inspector and building owner.
Captures signatures of the inspector and building owner.
The checklist is a pass/fail verification of key components, while the report provides a more detailed record of each door's results, including defects and overall compliance status. The report is more suitable for regulatory or audit purposes.
Yes, the fire door results section is repeatable, allowing you to record results for as many doors as needed. Each door is identified by its unique identifier.
If a door fails any check, select the appropriate fail result (e.g., 'fail' for self-closing). You can then document the defect in the defects section, including a photo of the issue.
The report covers common inspection points required by fire safety standards. However, acceptance depends on local regulations. It is advisable to verify that the report format meets specific authority requirements.
The report includes signature fields for the inspector and the building owner. Both parties should sign to acknowledge the findings and agree on any required actions.
Yes, once completed, you can export the report as a PDF. The export includes all inspection data, defects, photos, and signatures.
Enter inspection details and generate a ready-to-download document.